Skip to main content
Connect Schneider Access Expert to KODE OS for access control data integration

Overview

Use this integration to connect Schneider Access Expert (AccessXpert) to KODE OS. You can discover access devices and points, then monitor entries, exits, and access attempts for operations and reporting.

Supported Capabilities

  • Discover Devices & Points
  • Collect Sensor Data
  • Collect Non-Sensor Data

Prerequisites

  • An active account with Schneider Access Expert and access to their API or developer portal
  • Username and password credentials for the Schneider Access Expert system
  • KODE OS environment with access to Data Sources

Configure Connector in KODE OS

  1. Navigate to Data Sources in your building
  2. Click API Catalog and search for Schneider Access Expert
  3. Click + Add Datasource
  4. Fill in the fields below and complete the three-page setup flow

Discover Devices and Points

After configuring the connector, click Discover on the connector detail page. KODE OS will query the Schneider Access Expert system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in KODE OS. For more details on the discovery process, see the Discovery guide.

Devices and Points

When you discover devices from Schneider Access Expert, KODE OS maps them to the following device types and data points:

Access Controller

Canonical Type: default

What Data You Get

Point History

Time-series readings including is_tampered, door_forced_open, mask_door_forced_open, door_held_open, mask_door_held_open, door_contact_faulted, rex_faulted, latch_mode, and 13 more, collected at regular intervals from connected devices

Event Logs

System and security event records with timestamps, event types, and associated devices KODE OS maps Schneider Access Expert data to these standard fields:

Access Control

Access control records including card reader events, credential verification, and zone access KODE OS maps the collected data to these standard fields:

Polling Schedule

  • Point History — Default polling: 1 minutes (min: 1 minutes, max: 1 hours)
  • AccessControl — Default polling: 5 minutes (min: 5 minutes, max: 5 minutes)
  • EventLog — Default polling: 1 days (min: 1 days, max: 1 days)
For more details on collection modes, see the Data Collection guide.

Use Cases

Once connected, this integration enables you to:
  • Centralize access event monitoring across all entry points and zones
  • Generate audit trails for security compliance and investigation
  • Correlate access patterns with occupancy and energy data for building optimization

Troubleshooting

Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Schneider Access Expert system.
Verify the connector credentials have sufficient permissions in the Schneider Access Expert system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device enumeration.
Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Schneider Access Expert API.
Last modified on March 29, 2026